What Size MPPT Charge Controller for Van Solar?
An MPPT charge controller is rated by output amps, and you size it from your
array watts and battery voltage. The formula is
amps = (array watts ÷ system volts) × 1.25, then round up to the
next standard controller (20, 30, 40, 50, 60, 80, 100 A). The 1.25 factor is
NEC 690.8's continuous-current margin, and using the nominal battery voltage
(12 or 24V) rather than panel voltage keeps the result conservative.
Worked example
A 400 W array on a 12V system: (400 ÷ 12) × 1.25 = 41.7 A. Round
up to the next standard size and you need a 50 A MPPT
controller. Switch that same array to 24V and the current roughly halves to
(400 ÷ 24) × 1.25 = 20.8 A, so a 30 A controller does the job —
one reason larger builds move to 24V.
| Array | 12V controller | 24V controller |
|---|---|---|
| 200 W | 30 A | 20 A |
| 300 W | 40 A | 20 A |
| 400 W | 50 A | 30 A |
| 600 W | 80 A | 40 A |
| 800 W | 100 A | 50 A |
| 1,000 W | 100 A (split array) | 60 A |
Above roughly 100 A of output it is common to split the array across two controllers, which also adds redundancy. Always confirm the controller's maximum PV input voltage against your panels wired in series.
Quick start with a profile:
Your daily loads
Add each device with its watts and hours per day.
No loads yet. Add your fridge to start, or pick a profile above.
Solar array
—
Add loads to size your array.
Show the math
Battery bank
—
Show the math
Charge controller (MPPT)
—
Show the math
Inverter
—
Show the math
Battery-to-inverter wire & fuse
—
Show the math
Estimated cost
—
Budget street price → premium brands.